ADVANCED OPERATION
13
There are three detection areas for your choice:
Press “” or ” ” once to broaden the detection area.
Press “” or ” ” once to narrow the detection area.
4) LS (Level of Sensitivity) (Selected models only)
“LS” is to set the sensitivity of comparing two different images. The smaller the value is, the higher sensitivity for
motion detection.
5) SS (Spatial Sensitivity) (Selected models only)
“SS” is to set the sensitivity for detecting the size of one object (the number of the grids) on the screen. The
smaller the value is, the higher sensitivity for motion detection.
Note: The default setting of SS is 03, which means once an object is detected more than 3 grids, the
system will get triggered. So the value of SS must be less than the number of grids that you set up
for the motion detection area.
6) TS (Time of Sensitivity) (Selected models only)
“TS” is to set the sensitivity regarding how long one object stays in the detection area and triggers the recording.
Depending on the model you have, you may see either of the following methods:
a). Select a value -- The smaller the value is, the higher sensitivity for motion detection.
b). Select an option – HIGH / NORMAL / HIGH.
7) RE (Reference) (Selected models only)
“RE” is to set a reference for detection. The default value is 10, which means the DVR will compare 10 continuous
images at one time according to the sensitivity of LS, SS, TS simultaneously.
8) ALARM (Selected models only)
Select N.C. (Normally Closed) / N.O. (Normally open) / OFF for the alarm polarity. The default alarm value is OFF.
5.5. REMOTE (Selected models only)
In this menu list, you can set up remote devices to work properly.
Move to “REMOTE”, and press ”ENTER”. You will see the following submenu items:
1) TITLE
Show the camera title of each channel set in “CAMERA”.
2) DEVICE
Select the device type (CAMERA / PTZ) according to the connected camera for each channel.
3) ID
Set the ID number (0 ~ 255) for a PTZ camera. After connecting to a PTZ camera correctly, the default ID of the
PTZ camera will be shown on the screen.
4) PROTOCOL
Select NORMAL (our protocol) or P-D (PELCO-D) protocol.
5) RATE
Set the baud rate of each channel (2400 / 115200 / 9600 / 19200 / 57600 / 115200). For the connected cameras,
such as PTZ and speed dome cameras, etc., please make sure their baud rate setting is the same as the setting
here.
5.6. SYSTEM / SYSTEM INFO
In this menu list, you can check or change some system settings.
The submenu items are described below: